See Waz work

A real infrastructure event just came in. Watch Waz correlate alerts across systems, identify root cause, and draft the procedures your operator needs.

Incoming Event
Just now

Inlet temperature exceeding ASHRAE envelope: Row C, Rack C-12

highSource: Schneider EcoStruxureComponent: DM-Akron · Row C · Rack C-12
Thermal escalation: CRAC-08 reduced airflow, 4 servers throttling

3 Correlated Alerts Detected

CRAC-08 supply airflow lowSchneider
node_thermal_throttle = 1Prometheus
Inlet temp crossed 27°CSunbird

Topology

DM-Akron · Row C · Rack C-12 (42U). 4 production hosts in U18-U24 (db-prod-akron-04 in U22). Primary cooling: hot-aisle CRAC-08 (Schneider Galaxy VS InRow). Redundant: CRAC-07 (currently 78% load).

via Source of Truth

Health Signals

C-12 inlet temp 29.4°C (ASHRAE A1 ceiling 27°C); CRAC-08 supply airflow 62% of nominal; db-prod-akron-04 CPU package 84°C, entering thermal throttle; humidity 47% (normal).

via Prometheus + Netdata

Recent Logs

14:21:08 Schneider crac-08 alarm: SUPPLY_AIRFLOW_LOW; 14:21:33 prometheus node_thermal_throttle{host="db-prod-akron-04"}=1; 14:22:14 sunbird rack rack-c-12 inlet_temp_c=29.4 (threshold 27.0); 14:22:51 ipmi sensor cpu_temp warning on 3 hosts in C-12.

via Splunk

CorrelateRoot Cause AnalysisSOP & MOP Draft

This walkthrough runs entirely in your browser. The full investigation runs live in Spektro.

[01] The Relationship Graph

Waz maps how your facility connects

Every signal is clustered by relationship, power, network, cooling, so when an incident fires, Waz already knows its blast radius and isolates it instantly.

BATTERY14VOLTAGE17PSU3GENERATOR15POWER-A16BRANCH14BUDGET16BUS14BGP16PORTFLAP1RETURN20CRAC-0822HUMIDITY16AIRFLOW16CHILLER16REFRIG.14SENSOR14CRAC-08 airflowinfo · rca_ready
Healthy clusterActive incidentFocused · RCA ready

[02] The Core

Unified Architecture

Contextual Triage
The Agentic Operator correlates live telemetry with your Source of Truth to distinguish noise from signal.
Live Correlation Engine
CPU 92% CR-01
Packet Loss 18%
Interface Flapping
1Root Cause Found

WAN link failure on CR-01 causing cascading alerts across DM-Akron

90%
Inventory Sync
Connect any source of truth in seconds.
InventorySynced
MonitoringSynced
TicketingPolling
Adaptive Documentation

The AI decides what each incident actually needs, an MOP, SOP, EOP, JHA, or postmortem, and ships it with an evidence bundle and coverage score.

[03] Knowledge Base

A living knowledge base

Every procedure Waz drafts becomes a searchable, shareable record, an MOP, EOP, JHA, SOP, or postmortem, grounded in the incident that produced it.

Search the knowledge base
AllMOPEOPJHASOPPM
MOP

Replace CRAC-08 Return-Air Filter Under Reduced Cooling

crac-akron-08

Generated by
Waz
Incident
CRAC-08 supply airflow restricted
Risk class
Medium
Approval
Operator review required

1. Summary

Return-air filter on CRAC-08 has reached end of life (differential pressure 1.42" w.c.), cutting supply airflow to 62% of nominal and driving Rack C-12 inlet temps past the ASHRAE A1 ceiling. This procedure restores cooling capacity while protecting the throttled workloads in Row C.

2. Procedure

Spin up CRAC-07 to full and stage portable spot-cool at the Row C cold-aisle endcap. Drain db-prod-akron-04 to the secondary cluster. LOTO CRAC-08, replace the return-air filter, vacuum the coil face. Restore CRAC-08 and verify supply airflow at or above 95% of nominal.

Every artifact is exportable and shareable, with the full evidence bundle attached.

[04] Operators Always Approve

Humans + Agents

Spektro absorbs the hours of triage, correlation, and documentation. Your operators stay in the driver's seat for every production change. Every artifact is reviewed, every action logged.

  • Zero-Touch Context
  • Audit-Ready Logs
  • Human-in-the-loop Control
Waz
Online
Anomaly detected on PDU-B in rack-c-08-akron Phase imbalance climbing past tolerance.
Diagnosis: Failed PSU on db-prod-akron-04 cascading into PDU draw
MOP drafted: redundant PSU validation, controlled shutdown sequence, PSU swap window. JHA + EOP included. Evidence bundle attached.
Deliver MOP for Review →

Infrastructure Context

Sunbird + NetBox Synced
Rackrack-c-08-akron
PDU FeedB-side · 30A
StatusPhase Imbalance

[05] The Payoff

What operators get

Cut MTTR

Diagnosis and the procedure land in seconds, not hours.

End alarm fatigue

Correlated root causes replace thousands of raw alarms.

Protect uptime

Catch the failing unit before it cascades across the row.

Reclaim operator hours

The mechanical triage work stops landing on your team.