Your infrastructure is growing. Your team isn't.
The data exists. The incident context doesn't. Operators still stitch together alerts, telemetry, inventory, tickets, and runbooks before they can diagnose anything.
- 01
Scattered signals
Telemetry, operational signals, logs, tickets, and live infrastructure data are spread across disconnected systems.
- 02
Siloed intel
Critical runbook knowledge is locked away in outdated SOPs, static manuals, and inside individual engineers' heads.
- 03
Manual correlation
Operators must manually connect signals across systems before they can determine what actually happened.
- 04
Lost resolution
Valuable post-incident context and hard-won postmortem insights evaporate the moment the ticket is closed.
Live demo
Waz is an AI operator that reads your tools and drafts the procedure. Here is one alarm.
See Waz work
One alarm. Five systems. Scroll to watch Waz connect them.
CRAC-08 supply airflow restricted on Rack C-12
Correlated signals
- 14:21:08CRAC-08 SUPPLY_AIRFLOW_LOWSchneider EcoStruxure
- 14:21:33node_thermal_throttle=1 on db-prod-akron-04Prometheus
- 14:22:14C-12 inlet 29.4°C, above 27°C ASHRAE A1 recommendedSunbird
Investigation checks
0 of 5 completeWhat cooling asset serves Rack C-12, and what is the redundant pair?
Queuednetbox.get_asset
Is CRAC-08 delivering rated supply airflow?
Queuedbacnet.read
Can CRAC-07 cover C-12 and C-13 while CRAC-08 is degraded?
Queuedbacnet.read
Are C-12 hosts actually throttling, or is the inlet sensor wrong?
Queuedprometheus.query_range
Is there an overdue PM or change that explains the filter loading?
Queuedservicenow.search_records
Hypothesis
SupportedLoaded return-air filter on CRAC-08 is restricting supply airflow. That pushed C-12 inlet above the 27°C ASHRAE A1 recommended max and put four hosts into inlet-driven thermal throttle.
5 cited claims from connected sources.
- First signal
- 14:21:08
- MOP drafted
- 14:23:22 · 2 min 14 s
- Next
- Operator signs and runs it
Access
What Waz reads. What it writes.
Read-only to your infrastructure. Waz writes only drafts and incident messages, and an operator approves every draft.
Reads
Read-only credentials- Monitoring and BMSAlarms, cooling points, host telemetry



- DCIM and CMDBTopology, rack inlet and power, dependencies


- Network and securityPaths, flows, threat context


- LogsEvent history, in order


- Change and maintenanceOpen changes, PM tasks and their history

- PlaybooksExisting runbooks to draft from


Writes
Drafts and messages- Drafted MOPs, SOPs, and ticketsInto your ITSM, waiting for an operator to approve


- Messages to your teamIncident updates posted where on-call already works


Never
By design- Push configuration
- Restart services
- Change the state of any device
- Run a procedure without an operator
Enterprise plans include self-hosted and air-gapped deployment.
Security & TrustApproval and record
Operators approve. Every draft is kept.
The MOP, EOP, JHA, and PM change Waz drafted for CRAC-08, each waiting on the person who signs it.
Documents
Replace CRAC-08 return-air filter under reduced cooling
CRAC-08
- Owner
- Waz
- Risk class
- Medium
- Rack
- RACK-C-12
- Cooling
- CRAC-08 · pair CRAC-07
Why this action
Filter ΔP is 1.42 in. w.c. against a 1.0 replacement threshold. Supply airflow is 62% of nominal. This change restores airflow while protecting the four throttled hosts in U18-U24.
Before approval
- CRAC-07 is online and can take additional load. Spot-cool covers C-12 and C-13 while CRAC-08 is isolated.
- Spot-cool is staged at the Row C cold-aisle endcap.
- Operator review and sign-off. Waz does not execute it.
Risks
- Isolating CRAC-08 before CRAC-07 carries the load pushes remaining C-12 inlets higher.
- Inlet can climb toward the 32°C ASHRAE A1 allowable while the unit is offline.
Procedure
- [01]
Spin CRAC-07 toward 100% and confirm C-12 and C-13 inlet before any CRAC-08 work.
- [02]
Priority-drain db-prod-akron-04 to the Akron secondary cluster. Keep U18-U24 on watch.
- [03]
LOTO CRAC-08. Replace the return-air filter. Vacuum the coil face.
- [04]
Restore CRAC-08. Confirm supply airflow at or above 95% of nominal and filter ΔP below 0.5 in. w.c.
Verify recovery
- Supply airflow at or above 95% of nominal.
- Filter ΔP below 0.5 in. w.c.
- C-12 inlet stable at or below 24°C for 20 minutes.
Abort
If C-12 inlet approaches 32°C, restore CRAC-08 and stop. Do not continue the swap.
- Drafted by Waz
- 14:23:22
- Evidence
- 5 sources cited
- Sign-off
- Approval required
See Waz work an incident like yours.
A live walkthrough with our team, on the systems you run.